eISSN: 2449-8580
ISSN: 1734-3402
Family Medicine & Primary Care Review
Current issue Archive Manuscripts accepted About the journal Editorial board Reviewers Abstracting and indexing Subscription Contact Instructions for authors Publication charge Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
1/2022
vol. 24
 
Share:
Share:
abstract:
Original paper

Is early detection of eating disorders possible in Primary Care?

Paula Sofía Pérez Martín
1
,
José Antonio Martínez Pérez
2
,
Ana Espejo González
1

  1. PCP. Primary Care Physician, SERMAS, Madrid, Spain
  2. Medicine Department, University of Alcalá de Henares, Madrid, Spain
Family Medicine & Primary Care Review 2022; 24(1): 61–65
Online publish date: 2022/03/27
View full text Get citation
 
PlumX metrics:
Background
Eating disorders are considered an important public health problem, due to the chronicity and mortality to which they are associated. They are time-dependent diseases, in which early detection and treatment can improve the prognosis.

Objectives
The objective of our work was to assess the psychometric properties of the SCOFF questionnaire as an instrument to detect the presence of eating disorders quickly and reliably in a primary care centre.

Material and methods
Observational, cross-sectional and multicentre study carried out on 291 people in all the health centres of the capital of Guadalajara. Stratified, multistage and proportional random sampling according to age, gender and health centres. The study was carried out in 2 phases: completion of the SCOFF questionnaire and clinical interview. Sensitivity, specificity, positive and negative predictive value, global value, positive probability ratio, ROC curve, Cronbach’s alpha, and mean time to perform the test were observed.

Results
Sensitivity: 91.6% (95% CI: 71.8–100%); Specificity: 91% (95% CI: 87.5–94.5%); Positive predictive value: 30.5% (95% CI: 14.1–46.9%); Negative predictive value: 99.6% (95% CI: 98.6–100%); Positive probability ratio: 10.2 (95% CI: 6.8–15.4%); Efficiency: 91.1% (95% CI: 87.6–94.5%); Area under the ROC curve: 0.9099 (95% CI: 0.8082–1.0117); Cronbach’s α: 0.725; Mean performance time: 3.98 (± 0.12) minutes.

Conclusions
The SCOFF is a short questionnaire, easy and brief to fill out, reliable and with indications of validity and sufficient diagnostic sensitivity to be applied with guarantee in primary care centres.

keywords:

Primary Care – SCOFF questionnaire, ED – early detection, psychometric properties

 